Manual Euro-MERiDIAN
Chapter 10 Page 10 - 9
(v) KEYPADS
NOTE: Deluxe Keypad shown. Standard Keypad has no zone or output
terminals.
Zones are available only at nominated Addresses – see page 4-5
(vi) SET/UNSET TAG READERS
The same information is valid for the TMZ Module, which uses the
same PCB, except that OUTPUT 2 is a SOUNDER output, suitable for
driving a loudspeaker.
NOTE: Zones are available only at nominated Addresses – see page 4-5
Note: Keypad addressing is performed as a
software function whilst programming –
there are no address codin
g
switches.
Terminal Allocations:
D RS.485
1 0v
2 +12v
3
A
4
B
K EOL Zones
1 0v
2 +12v
3 Zone 1
4 Zone 2
M Output
1 Output 1
Terminal Allocations:
D RS.485
1 0v
2 +12v
3
A
4
B
K EOL Zones
1 0v
2 +12v
3 Zone 1
4 Zone 2
L Outputs
1 +12v
2 Output 1
3 Output 2
Note: Before powering up, the Zone Expander
Unit must be addressed, using the coding
switches – open switches to add up to the
address required.